6-35kV Triple-layer Half Catenary Co-extrusion Dry-cure CCV Line


Main Technical Data

Voltage class

XLPE

6~35kV

Conductor cross section

Cu

35~630 mm2

Al

50~800 mm2

Max. Weight of cable

10 kg/m

Outer diameter of cable

Φ75 mm

Wall thickness

Φ65 extruder for inner layer

0.5~2.0 mm

Φ150 extruder for insulation layer

2.5~10.5 mm

Φ90 extruder for outer layer

0.5~2.0 mm

Length of vulcanizing tube

120m

Heating section

L=36m 6m×6

Pre-cooling section

L=12 m6m×2

Water cooling

L=54m 6m×9

Needed area of main platform (L×W)

L×W≥24m×18 m

Height of 3-platform 

≥10m

Needed length of workshop (premises)

≥135 m

Nitrogen gas

Pressure

2.0~2.5 MPa

Purity

99.5 %

Consumption

0.4~1.8 m3 /h

Volume of N2 tank

5 m3

Cooling water

Pressure

0.2~2 MPa

Circulation consumption

12.5m3 /h

Compressed air

Pressure

0.6~0.8 MPa

Standard consumption

0.8 m3 /h

Installed capacity

750 kVA

Two power incoming lines

(3×185 mm2 , 3×240 mm2)